GENERATORS

GENERATOR HELIOS 35

The HELIOS-35 source is designed for X-ray applications with anode voltage adjustment range up to a maximum of 70kV. The device is characterized by its small size, high conversion efficiency and an analogue digital interface with RS-232 and Ethernet that simplify the integration.

The sophisticated inverter-type control circuit provides excellent anode voltage regulation with low crest noise to the X-ray tube. The inverter regulates the filament power, thus achieving a high stability of the regulating power which contributes to the anodic current stability and to the X-ray flux intensity.

GENERATOR HELIOS 50

The HELIOS 50 source is designed for X-ray applications with anode voltage adjustment range up to a maximum of 80kV. The device is characterized by its small size, high conversion efficiency and an analogue digital interface, RS-232 and Ethernet, that simplify integration.

The sophisticated inverter control circuit provides excellent anode voltage regulation, with low crest noise to the X-ray tube. The inverter regulates the filament power, thus achieving a high stability of the regulating power that contributes to the stability of the anode current and thus to the intensity of the X-ray flux.

GENERATOR HELIOS 100

The HELIOS-100 source is designed for X-ray applications with anodic voltage regulation range up to a maximum of 100kV. The device is characterized by its reduced dimensions with high conversion efficiency and an analogical digital interface, RS-232 and Ethernet, making integration easier.

GENERATOR HELIOS 200/300

The HELIOS 200 and 300 X-ray generators are designed for X-ray applications with anode voltage regulation range up to a maximum of 80 kV. The devices are characterized by having radiogen dose power with high conversion efficiency and an analogue digital interface with RS-232 and Ethernet, which simplify integration.

The sophisticated inverter control circuit provides excellent regulation of the anode voltage, with low crest noise to the X-ray tube. The inverter regulates the filament power, thus achieving a high stability of the regulation power which contributes to the stability of the anode current and therefore to the intensity of the X-ray flux consequently giving an accurate process analysis.

X-RAY MONOBLOC

FCX 3.5 /FCX 15 /FCX 15.P /FCX 30

Monoblock generators in aluminum casing for better thermal dissipation in oil treatment with high frequency transformer, feedback circuit for x-ray parameters and rotating anode tube insert.
Developed and designed for fluoroscopy in C-Arms powered by a 15 kW inverter (FCX 15 / 15.P monoblocs) and 30 kW (FCX 30 monobloc).

VETERINARY RADIOLOGY

EXAMINER TABLE TOP

Table top length: 150 cm standard

(other sizes available on request)

4 ways with mechanical brakes

Max weight capacity for patient support table 100 kg

Table absorption thickness 5mm 0,8mm

PHILOSOPHY HF400 Standard

• Welded sheet metal structure painted with epoxy powder
• Patient support table 4-ways mechanical brakes
• X-ray steel plate cassette
• Removable anti-scatter grid
• Inverter inside the table

PHILOSOPHY HF400 Plus

• Welded sheet metal structure painted with epoxy powder
• Patient support table 4-ways mechanical brakes
• X-ray steel plate cassette

• Removable anti-scatter grid
• Inverter inside the table

PHILOSOPHY HF400-FT Floor Track

• Welded sheet metal structure painted with epoxy powder
• Patient support table 4-ways mechanical brakes 2mt.
• X-ray steel plate cassette
• Removable anti-scatter grid
• Inverter inside the table

INVERTER

HF INVERTER
  • High power inverter with IGBT technology
  • Intended for monoblock 30kW 40 kHz
  • Applied in x-ray systems
  • Control system with PC TOUCHSCREEN and dedicate software.
  • Radiological parameters with continuous control during emission.